MV 90 Indulink CU/ XLPE/ WS/ LLDPE 5 kV 100% and 133%

Construction

1- Conductor: Compact class B stranded soft annealed bare copper as per ASTM B-496.
2- Conductor shield: Extruded thermoset semi-conducting stress control layer.
3- Insulation: Tree-retardant cross-linked polyethylene (TR-XLPE).
4- Insulation shield: Extruded thermoset strippable semi-conducting insulation shield.
5- Copper wires shield:one-third neutral concentric round annealed bare copper wires helically applied over the insulation shield.
6- Jacket:black sunlight linear low density thermoplastic polyethylene (LLDPE).

Standards

ASTM B-3 - Standard Specification for Soft or Annealed Copper Wire
ASTM B-496 - Standard Specification for Compact Round Concentric-Lay-Stranded Copper Conductors UL 1072 - Medium-Voltage Power Cables
ICEA S-93-639 - 5-46 kV Shielded Power Cable for use in the Transmission and Distribution of Electric Energy

Data


COPPER CONDUCTOR, 5 kV 100 % INSULATION LEVEL, 90 MILS

PRODUCT CODE COND. SIZE (AWG or kcmil) NOMINAL CONDUCTOR DIAMETER (inches) NOMINAL INSULATION DIAM.(inches) NOMINAL INSULATION SHIELD DIAM. (inches) NOMINAL DIAMETER OVER JACKET (inches) APPROX. WEIGHT (lb/kft) AMPACITY (A) CONDUIT SIZE (inches)
COPPER TOTAL CONDUIT IN AIR (1) UNDERGROUND DUCT (2)
821501045 4 0.21 0.469 0.531 0.794 488 400 97 110 3
821501047 2 0.27 0.522 0.585 0.878 662 516 130 145 3
821501048 1 0.30 0.554 0.617 0.909 815 596 155 170 3
821501049 1/0 0.33 0.591 0.654 0.946 1032 707 180 195 3
821501050 2/0 0.37 0.631 0.694 0.986 1291 836 205 220 3
821501051 3/0 0.42 0.677 0.740 1.032 1630 1005 240 250 3
821501052 4/0 0.47 0.731 0.794 1.086 2066 1218 280 290

3 ½

821501053 250 0.52 0.774 0.837 1.130 2433 1397 315 320

3 ½

821501054 350 0.61 0.869 0.932 1.224 3390 1857 385 385

3 ½

821501057 500 0.73 0.991 1.054 1.447 4868 2620 475 470 4
821501060 750 0.90 1.156 1.219 1.612 7359 3791 600 585 5
821501062 1000 1.06 1.312 1.375 1.828 9752 4987 690 670 6

COPPER CONDUCTOR, 5 kV 133 % INSULATION LEVEL, 115 MILS

PRODUCT CODE COND. SIZE (AWG or kcmil) NOMINAL CONDUCTOR DIAMETER (inches) NOMINAL INSULATION DIAM.(inches) NOMINAL INSULATION SHIELD DIAM. (inches) NOMINAL DIAMETER OVER JACKET (inches) APPROX. WEIGHT (lb/kft) AMPACITY (A) CONDUIT SIZE (inches)
COPPER TOTAL CONDUIT IN AIR (1) UNDERGROUND DUCT (2)
823201045 4 0.21 0.489 0.552 0.844 488 426 97 110 3
823201047 2 0.27 0.543 0.606 0.898 662 527 130 145 3
823201048 1 0.30 0.574 0.637 0.930 815 608 155 170 3
839201049 1/0 0.33 0.612 0.675 0.967 1032 719 180 195 3
823201050 2/0 0.37 0.651 0.714 1.006 1291 850 205 220 3
823201051 3/0 0.42 0.698 0.761 1.053 1630 1018 240 250 3
823201052 4/0 0.47 0.752 0.815 1.107 2066 1232 280 290

3 ½

823201053 250 0.52 0.795 0.858 1.150 2433 1412 315 320

3 ½

823201054 350 0.61 0.889 0.952 1.244 3390 1873 385 385

4

823201057 500 0.73 1.011 1.074 1.467 4868 2639 475 470 4
823201060 750 0.90 1.177 1.240 1.693 7359 3876 600 585 5
823201062 1000 1.06 1.332 1.395 1.848 9752 5010 690 670 6