MV 90 Indulink CU/ XLPE/ CT/ PVC 25 kV 100% and 133% I.L.

Construction

1- Conductor: Compact class B stranded soft annealed bare copper as per ASTM B-496.
2- Conductor shield: Extruded thermoset semi-conducting stress control layer.
3- Insulation: Tree-retardant cross-linked polyethylene (TR-XLPE).
4- Insulation shield: Extruded thermoset strippable semi-conducting insulation shield.
5- Copper wires shield:5 mils bare copper tape helically applied with 25 % minimum overlap.
6- Jacket: black flame retardant, sunlight and oil resistant I polyvinyl chloride (PVC).

Standards

ASTM B-3 - Standard Specification for Soft or Annealed Copper Wire
ASTM B-496 - Standard Specification for Compact Round Concentric-Lay-Stranded Copper Conductors
UL 1072 - Medium-Voltage Power Cables
ICEA S-93-639 - 5-46 kV Shielded Power Cable for use in the Transmission and Distribubtion of Electric Energy UL 1685 - Safety Vertical-Tray Fire-Propagation and Smoke-Release Test for Electrical and Optical-Fiber Cables IEEE 1202 – Flame-propagation testing of wire and cable.

Data


COPPER CONDUCTOR, 25 kV 100 % INSULATION LEVEL, 260 MILS

PRODUCT CODE COND. SIZE (AWG or kcmil) NOMINAL CONDUCTOR DIAMETER (inches) NOMINAL INSULATION DIAM.(inches) NOMINAL INSULATION SHIELD DIAM. (inches) NOMINAL DIAMETER OVER JACKET (inches) APPROX. WEIGHT (lb/kft) AMPACITY (A) CONDUIT SIZE (inches)
COPPER TOTAL CONDUIT IN AIR (1) UNDERGROUND DUCT (2) TRAY (3)
837301048 1 0.30 0.874 0.937 1.113 790 1713 170 175 3 ½
837301049 1/0 0.33 0.911 0.974 1.150 950 1921 195 200 195 3 ½
837301050 2/0 0.37 0.950 1.013 1.189 1151 2172 225 230 225 3 ½
837301051 3/0 0.42 0.997 1.060 1.236 1403 2483 260 260 260 3 ½
837301052 4/0 0.47 1.051 1.114 1.290 1719 2868 295 295 300 4
837301053 250 0.52 1.094 1.157 1.333 1997 3201 330 325 330 4
837301054 350 0.61 1.189 1.252 1.427 2713 4037 395 390 410

4

837301057 500 0.73 1.311 1.374 1.550 3810 5289 480 465 510

5

837301060 750 0.90 1.476 1.539 1.775 5606 7496 585 565 655 5
837301062 1000 1.06 1.631 1.694 1.930 7407 9512 675 640 780 6

COPPER CONDUCTOR, 25 kV 133 % INSULATION LEVEL, 320 MILS

PRODUCT CODE COND. SIZE (AWG or kcmil) NOMINAL CONDUCTOR DIAMETER (inches) NOMINAL INSULATION DIAM.(inches) NOMINAL INSULATION SHIELD DIAM. (inches) NOMINAL DIAMETER OVER JACKET (inches) APPROX. WEIGHT (lb/kft) AMPACITY (A) CONDUIT SIZE (inches)
COPPER TOTAL CONDUIT IN AIR (1) UNDERGROUND DUCT (2) TRAY (3)
839101048 1 0.30 0.994 1.057 1.233 616 1951 170 175 4
839101049 1/0 0.33 1.031 1.094 1.270 724 2165 195 200 195 4
839101050 2/0 0.37 1.071 1.134 1.310 860 2423 225 230 225 4
839101051 3/0 0.42 1.117 1.180 1.356 1029 2742 260 260 260 4
839101052 4/0 0.47 1.171 1.234 1.410 1241 3136 295 295 300 5
839101053 250 0.52 1.215 1.278 1.453 1428 3477 330 325 330 5
839101054 350 0.61 1.309 1.372 1.548 1906 4329 395 390 410

5

839101057 500 0.73 1.431 1.494 1.730 2638 5797 480 465 510

5

839101060 750 0.90 1.596 1.659 1.895 3833 7851 585 565 655 6
839101062 1000 1.06 1.752 1.815 2.051 5031 9894 675 640 780 6