1- Conductor: Class B compact stranded 1350 aluminum as per ASTM B-400.
2- Conductor shield: Extruded thermoset semi-conducting stress control layer.
3- Insulation: Tree-retardant cross-linked polyethylene (TR-XLPE).
4- Insulation shield: Extruded thermoset strippable semi-conducting insulation shield.
5- Copper wires shield: one-third neutral concentric round annealed bare copper wires elically applied over the insulation shield.
6- Jacket: black flame retardant, sunlight and oil resistant I polyvinyl chloride (PVC).

Standards

ASTM B-400 - Standard Specification for Compact Round Concentric-Lay-Stranded Aluminum 1350 Conductors ASTM B-3 - Standard Specification for Soft or Annealed Copper Wire
UL 1072 - Medium-Voltage Power Cables
ICEA S-93-639 - 5-46 kV Shielded Power Cable for use in the Transmission and Distribubtion of Electric Energyc

Data


ALUMINUM CONDUCTOR, 15 kV 100 % INSULATION LEVEL, 90 MILS

PRODUCT CODECOND. SIZE (AWG or kcmil)NOMINLA CONDUCTOR DIAMETER (inches)NOMINAL INSULATION DIAM. (inches)NOMINAL INSULATION SHIELD DIAM. (inches)NOMINAL DIAMETER OVER JACKET (inches)APPROX. WEIGHT (lb/kft)AMPACITY (A)CONDUIT SIZE (inches)
ALUMINUMCOPPERTOTALCONDUIT IN AIR (1)UNDERGROUND DUCT (2)
84130104720.270.6820.7451.03714019611401151203
84130104810.300.7140.7771.06917619612161301353
8413010491/00.330.7510.8141.10622319613091501553
8413010502/00.370.7910.8541.14627922914431751753 ½
8413010513/00.420.8370.9001.19235429516332002003 ½
8413010524/00.470.8910.9541.24644536018492302303 ½
8413010532500.520.9340.9971.2895274262043255250

4

8413010543500.611.0291.0921.3847365892515310305

4

8413010575000.731.1511.2141.50610618193194385370

5

8413010607500.901.3161.3791.8321592125247554854556
84130106210001.061.4721.5351.9872133167058985655256

ALUMINUM CONDUCTOR, 15 kV 133 % INSULATION LEVEL, 220 MILS

PRODUCT CODECOND. SIZE (AWG or kcmil)NOMINLA CONDUCTOR DIAMETER (inches)NOMINAL INSULATION SHIELD DIAM. (inches)NOMINAL INSULATION SHIELD DIAM. (inches)NOMINAL DIAMETER OVER JACKET (inches)APPROX. WEIGHT (lb/kft)AMPACITY (A)CONDUIT SIZE (inches)
ALUMINUMCOPPERTOTALCONDUIT IN AIR (1)UNDERGROUND DUCT (2)
84300104720.270.7720.8351.15914019612891151203 ½
84300104810.300.8040.8671.19617619613691301353 ½
8430010491/00.330.8410.9041.23522319614671501553 ½
8430010502/00.370.8800.9431.28227922916061751753 ½
8430010513/00.420.9270.9901.33635429518022002003 ½
8430010524/00.470.9811.0441.37944536020252302304
8430010532500.521.0241.0871.4745274262225255250

4

8430010543500.611.1191.1811.5967365892708310305

5

8430010575000.731.2411.3041.92210618193403385370

5

8430010607500.901.4061.4692.0771592125250084854556