• Sales +1 (587) 885-1422  •  Follow us  

Share:     

Download:

MV 90 Indulink AL/ XLPE/ WS/ LLDPE 25 kV 100% and 133%

Construction

1- Conductor: Class B compact stranded 1350 aluminum as per ASTM B-400.
2- Conductor shield: Extruded thermoset semi-conducting stress control layer.
3- Insulation: Tree-retardant cross-linked polyethylene (TR-XLPE).
4- Insulation shield: Extruded thermoset strippable semi-conducting insulation shield.
5- Copper wires shield: one-third neutral concentric round annealed bare copper wires elically applied over the insulation shield.
6- Jacket: black sunlight linear low density thermoplastic polyethylene (LLDPE).

Standards

ASTM B-400 - Standard Specification for Compact Round Concentric-Lay-Stranded Aluminum 1350 Conductors ASTM B-3 - Standard Specification for Soft or Annealed Copper Wire
UL 1072 - Medium-Voltage Power Cables
ICEA S-93-639 - 5-46 kV Shielded Power Cable for use in the Transmission and Distribubtion of Electric Energyc

Data


ALUMINUM CONDUCTOR, 25 kV 100 % INSULATION LEVEL. 260 MILS

PRODUCT CODE COND. SIZE (AWG or kcmil) NOMINAL CONDUCTOR DIAMETER (inches) NOMINAL INSULATION DIAM.(inches) NOMINAL INSULATION SHIELD DIAM. (inches) NOMINAL DIAMETER OVER JACKET (inches) APPROX. WEIGHT (lb/kft) AMPACITY (A) CONDUIT SIZE (inches)
ALUMINUM COPPER TOTAL CONDUIT IN AIR (1) UNDERGROUND DUCT (2)
829001048 1 0.30 0.874 0.937 1.229 176 196 617 130 135 3 ½
829001049 1/0 0.33 0.911 0.974 1.266 223 196 660 150 155 3 ½
829001050 2/0 0.37 0.950 1.013 1.306 279 229 723 175 175 4
829001051 3/0 0.42 0.997 1.060 1.352 354 295 812 200 200 4
829001052 4/0 0.47 1.051 1.114 1.406 445 360 913 230 230

4

829001053 250 0.52 1.094 1.157 1.449 527 426 1003 255 250

5

829001054 350 0.61 1.189 1.252 1.544 736 589 1223 310 305

5

829001057 500 0.73 1.311 1.374 1.726 1061 819 1603 385 370 5
829001060 750 0.90 1.476 1.539 1.992 1592 1252 2219 485 455 5
829001062 1000 1.06 1.631 1.694 2.147 2133 1670 2744 565 525 6

ALUMINUM CONDUCTOR, 25 kV 133 % INSULATION LEVEL, 115 MILS

PRODUCT CODE COND. SIZE (AWG or kcmil) NOMINAL CONDUCTOR DIAMETER (inches) NOMINAL INSULATION DIAM.(inches) NOMINAL INSULATION SHIELD DIAM. (inches) NOMINAL DIAMETER OVER JACKET (inches) APPROX. WEIGHT (lb/kft) AMPACITY (A) CONDUIT SIZE (inches)
ALUMINUM COPPER TOTAL CONDUIT IN AIR (1) UNDERGROUND DUCT (2)
830701048 1 0.30 0.994 1.057 1.349 176 196 716 130 135 3 ½
830701049 1/0 0.33 1.031 1.094 1.387 223 196 763 150 155 4
830701050 2/0 0.37 1.071 1.134 1.426 279 229 829 175 175 4
830701051 3/0 0.42 1.117 1.180 1.472 354 295 921 200 200 4
830701052 4/0 0.47 1.171 1.234 1.526 445 360 1026 230 230

5

830701053 250 0.52 1.215 1.278 1.570 527 426 1120 255 250

5

830701054 350 0.61 1.309 1.372 1.724 736 589 1412 310 305

5

830701057 500 0.73 1.431 1.494 1.846 1061 819 1741 385 370 6
830701060 750 0.90 1.596 1.659 2.112 1592 1252 2376 485 455 6
830701062 1000 1.06 1.752 1.815 2.268 2133 1670 2912 565 525 7