• Sales +1 (587) 885-1422  •  Follow us  

Share:     

Download:

MV 90 Indulink AL/ XLPE/ WS/ LLDPE 15 kV 100% and 133%

Construction

1- Conductor: Class B compact stranded 1350 aluminum as per ASTM B-400.
2- Conductor shield: Extruded thermoset semi-conducting stress control layer.
3- Insulation: Tree-retardant cross-linked polyethylene (TR-XLPE).
4- Insulation shield: Extruded thermoset strippable semi-conducting insulation shield.
5- Copper wires shield: one-third neutral concentric round annealed bare copper wires elically applied over the insulation shield.
6- Jacket: black sunlight linear low density thermoplastic polyethylene (LLDPE).

Standards

ASTM B-400 - Standard Specification for Compact Round Concentric-Lay-Stranded Aluminum 1350 Conductors ASTM B-3 - Standard Specification for Soft or Annealed Copper Wire
UL 1072 - Medium-Voltage Power Cables
ICEA S-93-639 - 5-46 kV Shielded Power Cable for use in the Transmission and Distribubtion of Electric Energyc

Data


ALUMINUM CONDUCTOR, 15 kV 100 % INSULATION LEVEL, 90 MILS

PRODUCT CODE COND. SIZE (AWG or kcmil) NOMINLA CONDUCTOR DIAMETER (inches) NOMINAL INSULATION DIAM. (inches) NOMINAL INSULATION SHIELD DIAM. (inches) NOMINAL DIAMETER OVER JACKET (inches) APPROX. WEIGHT (lb/kft) AMPACITY (A) CONDUIT SIZE (inches)
ALUMINUM COPPER TOTAL CONDUIT IN AIR (1) UNDERGROUND DUCT (2)
828901047 2 0.27 0.682 0.745 1.037 140 196 467 115 120 3
828901048 1 0.30 0.714 0.777 1.069 176 196 499 130 135 3
828901049 1/0 0.33 0.751 0.814 1.106 223 196 539 150 155 3
828901050 2/0 0.37 0.791 0.854 1.146 279 229 598 175 175 3 ½
828901051 3/0 0.42 0.837 0.900 1.192 354 295 682 200 200 3 ½
828901052 4/0 0.47 0.891 0.954 1.246 445 360 777 230 230 3 ½
828901053 250 0.52 0.934 0.997 1.289 527 426 863 255 250

4

828901054 350 0.61 1.029 1.092 1.384 736 589 1072 310 305

4

828901057 500 0.73 1.151 1.214 1.506 1061 819 1375 385 370

5

828901060 750 0.90 1.316 1.379 1.832 1592 1252 2026 485 455 6
828901062 1000 1.06 1.472 1.535 1.987 2133 1670 2534 565 525 6

ALUMINUM CONDUCTOR, 15 kV 133 % INSULATION LEVEL, 220 MILS

PRODUCT CODE COND. SIZE (AWG or kcmil) NOMINLA CONDUCTOR DIAMETER (inches) NOMINAL INSULATION SHIELD DIAM. (inches) NOMINAL INSULATION SHIELD DIAM. (inches) NOMINAL DIAMETER OVER JACKET (inches) APPROX. WEIGHT (lb/kft) AMPACITY (A) CONDUIT SIZE (inches)
ALUMINUM COPPER TOTAL CONDUIT IN AIR (1) UNDERGROUND DUCT (2)
830601047 2 0.27 0.772 0.835 1.159 140 196 529 115 120 3 ½
830601048 1 0.30 0.804 0.867 1.196 176 196 563 130 135 3 ½
830601049 1/0 0.33 0.841 0.904 1.235 223 196 605 150 155 3 ½
830601050 2/0 0.37 0.880 0.943 1.282 279 229 666 175 175 3 ½
830601051 3/0 0.42 0.927 0.990 1.336 354 295 753 200 200 3 ½
830601052 4/0 0.47 0.981 1.044 1.379 445 360 851 230 230 4
830601053 250 0.52 1.024 1.087 1.474 527 426 940 255 250

4

830601054 350 0.61 1.119 1.181 1.596 736 589 1155 310 305

5

830601057 500 0.73 1.241 1.304 1.922 1061 819 1465 385 370

5

830601060 750 0.90 1.406 1.469 2.077 1592 1252 2132 485 455 6
830601062 1000 1.06 1.561 1.624 1.159 2133 1670 2650 565 525 6