Share:     

Download:

MV 90 EPRONAX AL/ EPR/ WS/ PVC 15 kV 100% and 133% I.L.

Construction

1- Conductor: Class B compact stranded 1350 aluminum as per ASTM B-400.
2- Conductor shield: Extruded thermoset semi-conducting stress control layer.
3- Insulation: Ethylene propylene rubber (EPR).
4- Insulation shield: Extruded thermoset strippable semi-conducting insulation shield.
5- Copper wires shield: one-third neutral concentric round annealed bare copper wires helically applied over the insulation shield.
6- Jacket: black flame retardant, sunlight and oil resistant I polyvinyl chloride (PVC).

Standards

STM B-400 - Standard Specification for Compact Round Concentric-Lay-Stranded Aluminum 1350 Conductors ASTM B-3 - Standard Specification for Soft or Annealed Copper Wire
UL 1072 - Medium-Voltage Power Cables
ICEA S-93-639 - 5-46 kV Shielded Power Cable for use in the Transmission and Distribubtion of Electric Energy

Data


ALUMINUM CONDUCTOR, 15 kV 100 % INSULATION LEVEL, 90 MILS

PRODUCT CODECOND. SIZE (AWG or kcmil)NOMINAL CONDUCTOR DIAMETER (inches)NOMINAL INSULATION DIAM.(inches)NOMINAL INSULATION SHIELD DIAM. (inches)NOMINAL DIAMETER OVER JACKET (inches)APPROX. WEIGHT (lb/kft)AMPACITY (A)CONDUIT SIZE (inches)
ALUMINUMCOPPERTOTALCONDUIT IN AIR (1)UNDERGROUND DUCT (2)TRAY (3)
84030104720.270.6820.7451.03714019612071151203
84030104810.300.7140.7771.06917619612871301353
8403010491/00.330.7510.8141.10622319613851501551503
8403010502/00.370.7910.8541.14627922915251751751703
8403010513/00.420.8370.9001.19235429517212002002003
8403010524/00.470.8910.9541.2464453601944230230230

3 ½

8403010532500.520.9340.9971.2895274262143255250260

3 ½

8403010543500.611.0291.0921.3847365892628310305320

4

8403010575000.731.1511.2141.506106181933233853703954
8403010607500.901.3161.3791.8321592125249064854555155
84020106210001.061.4721.5351.9872133167060705655256205

ALUMINUM CONDUCTOR, 15 kV 133 % INSULATION LEVEL, 115 MILS

PRODUCT CODECOND. SIZE (AWG or kcmil)NOMINAL CONDUCTOR DIAMETER (inches)NOMINAL INSULATION DIAM.(inches)NOMINAL INSULATION SHIELD DIAM. (inches)NOMINAL DIAMETER OVER JACKET (inches)APPROX. WEIGHT (lb/kft)AMPACITY (A)CONDUIT SIZE (inches)
ALUMINUMCOPPERTOTALCONDUIT IN AIR (1)UNDERGROUND DUCT (2)TRAY (3)
84220104720.270.8040.8351.12714019613801151203
84220104810.300.8410.8671.15917619614651301353
8422010491/00.330.6910.9041.19622319615691501551503
8422010502/00.370.8800.9431.23527922917151751751703 ½
8422010513/00.420.9270.9901.28235429519182002002003 ½
8422010524/00.470.9811.0441.3364453602150230230230

3 ½

8422010532500.521.0241.0871.3795274262356255250260

3 ½

8422010543500.611.1191.1811.4747365892483310305320

4

8422010575000.731.2411.3041.596106181935713853703955
8422010607500.901.4061.4691.9221592125252044854555155
84220106210001.061.5611.6242.0772133167063925655256206