MV 90 Indulink AL / XLPE / CT / PVC 15 kV 100% and 133% I.L.

Construction

1- Conductor: Class B compact stranded 1350 aluminum as per ASTM B-400.
2- Conductor shield: Extruded thermoset semi-conducting stress control layer.
3- Insulation: Tree-retardant cross-linked polyethylene (TR-XLPE).
4- Insulation shield: Extruded thermoset strippable semi-conducting insulation shield.
5- Copper wires shield:5 mils bare copper tape helically applied with 25 % minimum overlap.
6- Jacket: black flame retardant, sunlight and oil resistant I polyvinyl chloride (PVC).

Standards

ASTM B-400 - Standard Specification for Compact Round Concentric-Lay-Stranded Aluminum 1350 Conductors
UL 1072 - Medium-Voltage Power Cables
ICEA S-93-639 - 5-46 kV Shielded Power Cable for use in the Transmission and Distribubtion of Electric EnergyUL 1685 - Safety Vertical-Tray Fire-Propagation and Smoke-Release Test for Electrical and Optical-Fiber Cables
IEEE 1202 – Flame-propagation testing of wire and cable

Data


ALUMINUM CONDUCTOR, 15 kV 100 % INSULATION LEVEL, 175 MILS

PRODUCT CODE COND. SIZE (AWG or kcmil) NOMINAL CONDUCTOR DIAMETER (inches) NOMINAL INSULATION DIAM.(inches) NOMINAL INSULATION SHIELD DIAM. (inches) NOMINAL DIAMETER OVER JACKET (inches) APPROX. WEIGHT (lb/kft) AMPACITY (A) CONDUIT SIZE (inches)
ALUMINUM COPPER TOTAL CONDUIT IN AIR (1) UNDERGROUND DUCT (2) TRAY (3)
840801047 2 0.27 0.682 0.745 0.921 140 163 943 115 120 3
840801048 1 0.30 0.714 0.777 0.953 176 170 1019 130 135 3
840801049 1/0 0.33 0.751 0.814 0.990 223 178 1114 150 155 150 3
840801050 2/0 0.37 0.791 0.854 1.029 279 186 1220 175 175 170 3
840801051 3/0 0.42 0.837 0.900 1.076 354 196 1353 200 200 200 3
840801052 4/0 0.47 0.891 0.954 1.130 445 208 1512 230 230 230 3 ½
840801053 250 0.52 0.934 0.997 1.173 527 218 1648 255 250 260

3 ½

840801054 350 0.61 1.029 1.092 1.268 736 238 1977 310 305 320

4

840801057 500 0.73 1.151 1.214 1.390 1061 264 2456 385 370 395

4

840801060 750 0.90 1.316 1.379 1.555 1592 300 3195 485 455 515 5
840801062 1000 1.06 1.472 1.535 1.770 2133 334 4132 565 525 620 5

ALUMINUM CONDUCTOR, 15 kV 133 % INSULATION LEVEL, 220 MILS

PRODUCT CODE COND. SIZE (AWG or kcmil) NOMINAL CONDUCTOR DIAMETER (inches) NOMINAL INSULATION DIAM.(inches) NOMINAL INSULATION SHIELD DIAM. (inches) NOMINAL DIAMETER OVER JACKET (inches) APPROX. WEIGHT (lb/kft) AMPACITY (A) CONDUIT SIZE (inches)
ALUMINUM COPPER TOTAL CONDUIT IN AIR (1) UNDERGROUND DUCT (2) TRAY (3)
842601047 2 0.27 0.772 0.835 1.011 140 182 1094 115 120 3
842601048 1 0.30 0.804 0.867 1.042 176 189 1174 130 135 3
842601049 1/0 0.33 0.841 0.904 1.080 223 197 1273 150 155 150 3
842601050 2/0 0.37 0.880 0.943 1.119 279 206 1384 175 175 170 3 ½
842601051 3/0 0.42 0.927 0.990 1.166 354 216 1523 200 200 200 3 ½
842601052 4/0 0.47 0.981 1.044 1.220 445 227 1689 230 230 230 3 ½
842601053 250 0.52 1.024 1.087 1.263 527 237 1831 255 250 260

3 ½

842601054 350 0.61 1.119 1.181 1.357 736 257 2172 310 305 320

4

842601057 500 0.73 1.241 1.304 1.479 1061 284 2667 385 370 395

5

842601060 750 0.90 1.406 1.469 1.705 1592 320 3620 485 455 515 5
842601062 1000 1.06 1.561 1.624 1.860 2133 353 4394 565 525 620 6