Share:     

Download:

MV 105 Indulink CU/ XLPE/ CT/ PVC 15 kV 100% and 133% I.L.

Construction

1- Conductor: Compact class B stranded soft annealed bare copper as per ASTM B-496.
2- Conductor shield: Extruded thermoset semi-conducting stress control layer.
3- Insulation: Tree-retardant cross-linked polyethylene (TR-XLPE).
4- Insulation shield: Extruded thermoset strippable semi-conducting insulation shield.
5- Copper wires shield:5 mils bare copper tape helically applied with 25 % minimum overlap.
6- Jacket: black flame retardant, sunlight and oil resistant I polyvinyl chloride (PVC).

Standards

ASTM B-3 - Standard Specification for Soft or Annealed Copper Wire
ASTM B-496 - Standard Specification for Compact Round Concentric-Lay-Stranded Copper Conductors
UL 1072 - Medium-Voltage Power Cables
ICEA S-93-639 - 5-46 kV Shielded Power Cable for use in the Transmission and Distribubtion of Electric Energy UL 1685 - Safety Vertical-Tray Fire-Propagation and Smoke-Release Test for Electrical and Optical-Fiber Cables IEEE 1202 – Flame-propagation testing of wire and cable.

Data


COPPER CONDUCTOR, 15 kV 100 % INSULATION LEVEL, 175 MILS

PRODUCT CODECOND. SIZE (AWG or kcmil)NOMINAL CONDUCTOR DIAMETER (inches)NOMINAL INSULATION DIAM.(inches)NOMINAL INSULATION SHIELD DIAM. (inches)NOMINAL DIAMETER OVER JACKET (inches)APPROX. WEIGHT (lb/kft)AMPACITY (A)CONDUIT SIZE (inches)
COPPERTOTALCONDUIT IN AIR (1)UNDERGROUND DUCT (2)TRAY (3)
82480104720.270.6820.7450.92147012701651653
82480104810.300.7140.7770.95355614291901853
8248010491/00.330.7510.8140.99066416282152152203
8248010502/00.370.7910.8541.02979918712552452503
8248010513/00.420.8370.9001.07696821712902752903
8248010524/00.470.8910.9541.130118125443303153353 ½
8248010532500.520.9340.9971.17313682867365345370

3 ½

8248010543500.611.0291.0921.26818463681440415460

4

8248010575000.731.1511.2141.39025774905535500575

4

8248010607500.901.3161.3791.555377368756556107455
82480106210001.061.4721.5351.770497190377556908905

COPPER CONDUCTOR, 15 kV 133 % INSULATION LEVEL, 220 MILS

PRODUCT CODECOND. SIZE (AWG or kcmil)NOMINAL CONDUCTOR DIAMETER (inches)NOMINAL INSULATION DIAM.(inches)NOMINAL INSULATION SHIELD DIAM. (inches)NOMINAL DIAMETER OVER JACKET (inches)APPROX. WEIGHT (lb/kft)AMPACITY (A)CONDUIT SIZE (inches)
COPPERTOTALCONDUIT IN AIR (1)UNDERGROUND DUCT (2)TRAY (3)
82660104720.270.7720.8351.01148914211651653
82660104810.300.8040.8671.04257515841901853
8266010491/00.330.8410.9041.08068317882152152203
8266010502/00.370.8800.9431.11981920362552452503 ½
8266010513/00.420.9270.9901.16698823412902752903 ½
8266010524/00.470.9811.0441.220120027213303153353 ½
8266010532500.521.0241.0871.26313873050365345370

4

8266010543500.611.1191.1811.35718653877440415460

4

8266010575000.731.2411.3041.47925975116535500575

5

8266010607500.901.4061.4691.705379372996556107455
82660106210001.061.5611.6241.860499093007556908906