MV 105 EPRONAX AL/ EPR/ CT/ PVC 8 kV 100% and 133% I.L.

Construction

1- Conductor: Class B compact stranded 1350 aluminum as per ASTM B-400.
2- Conductor shield: Extruded thermoset semi-conducting stress control layer.
3- Insulation: Ethylene propylene rubber (EPR).
4- Insulation shield: Extruded thermoset strippable semi-conducting insulation shield.
5- Copper wires shield: 5 mils bare copper tape helically applied with 25 % minimum overlap.
6- Jacket: black flame retardant, sunlight and oil resistant I polyvinyl chloride (PVC).

Standards

ASTM B-400 - StandaASTM B-400 - Standard Specification for Compact Round Concentric-Lay-Stranded Aluminum 1350 Conductors UL 1072 - Medium-Voltage Power Cables
ICEA S-93-639 - 5-46 kV Shielded Power Cable for use in the Transmission and Distribution of Electric Energy UL 1685 - Safety Vertical-Tray Fire-Propagation and Smoke-Release Test for Electrical and Optical-Fiber Cables IEEE 1202 – Flame-propagation testing of wire and cable

Data


ALUMINUM CONDUCTOR, 8 kV 100 % INSULATION LEVEL, 115 MILS

PRODUCT CODE COND. SIZE (AWG or kcmil) NOMINLA CONDUCTOR DIAMETER (inches) NOMINAL ISULATION DIAM. (inches) NOMINAL INSULATION SHIELD DIAM. (inches) NOMINAL DIAMETER OVER JACKET (inches) APPROX. WEIGHT (lb/kft) AMPACITY (A) CONDUIT SIZE (inches)
ALUMINUM COPPER TOTAL CONDUIT IN AIR (1) UNDERGROUND DUCT (2) TRAY(3)
830901045 4 0.21 0.518 0.581 0.727 88 128 656 94 98 3
830901047 2 0.27 0.572 0.635 0.781 140 139 769 130 130 3
830901048 1 0.30 0.604 0.667 0.813 176 146 842 150 145 3
830901049 1/0 0.33 0.641 0.704 0.880 223 154 982 170 165 170 3
830901050 2/0 0.37 0.680 0.743 0.919 279 163 1085 200 190 195 3
830901051 3/0 0.42 0.727 0.790 0.966 354 173 1215 225 215 225 3
830901052 4/0 0.47 0.781 0.844 1.020 445 185 1371 260 245

260

3
830901053 250 0.52 0.824 0.887 1.063 527 194 1504 290 270

290

3
830901054 350 0.61 0.919 0.981 1.157 736 214 1827 350 330

360

3 ½
830901057 500 0.73 1.041 1.104 1.279 1061 241 2298 430 400 450 4
830901060 750 0,90 1.206 1.269 1.445 1592 277 3027 540 490 585 5
830901062 1000 1.06 1.361 1.424 1.600 2133 310 3754 640 565 705 5

ALUMINUM CONDUCTOR, 8 kV 133 % INSULATION LEVEL, 140 MILS

PRODUCT CODE COND. SIZE (AWG or kcmil) NOMINLA CONDUCTOR DIAMETER (inches) NOMINAL INSULATION DIAM. (inches) NOMINAL INSULATION SHIELD DIAM. (inches) NOMINAL DIAMETER OVER JACKET (inches) APPROX. WEIGHT (lb/kft) AMPACITY (A) CONDUIT SIZE (inches)
ALUMINUM COPPER TOTAL CONDUIT IN AIR (1) UNDERGROUND DUCT (2) TRAY(3)
832901045 4 0.21 0.569 0.631 0.777 88 138 735 94 98 3
832901047 2 0.27 0.622 0.685 0.861 140 150 902 130 130 3
832901048 1 0.30 0.654 0.717 0.893 176 157 979 150 145 3
832901049 1/0 0.33 0.691 0.754 0.930 223 165 1074 170 165 170 3
832901050 2/0 0.37 0.731 0.794 0.970 279 174 1181 200 190 195 3
832901051 3/0 0.42 0.777 0.840 1.016 354 184 1315 225 215 225 3
832901052 4/0 0.47 0.831 0.894 1.070 445 195 1476 260 245

260

3
832901053 250 0.52 0.874 0.937 1.113 527 205 1613 290 270

290

3 ½
832901054 350 0.61 0.969 1.032 1.208 736 225 1945 350 330

360

3 ½
832901057 500 0.73 1.091 1.154 1.330 1061 252 2427 430 400 450 4
832901060 750 0,90 1.256 1.319 1.495 1592 287 3171 540 490 585 5
832901062 1000 1.06 1.412 1.475 1.711 2133 321 4104 640 565 705 5